Inspection of In-Place Bridges Constructed with Grouted Post-Tensioning Ducts

Principal Investigator(s):

Andrea Schokker, Professor, UMD-Civil Engineering

Project summary:

This research focused on post-tensioned bridges built in Minnesota prior to 2003. The scope was limited to providing a targeted check of bridges most likely to have grouting-related corrosion problems based on a review of plans and inspection notes. The project consisted of three phases: (1) review of plans and inspection reports of 40 post-tensioned bridges constructed prior to 2003; (2) selection of 10 bridges for a limited onsite inspection of the exterior of the bridge; and (3) invasive inspection of three select bridges. The bridges were selected to represent different bridge construction types to provide a spot check of the post-tensioned bridge inventory in Minnesota. One of the three bridges has corrosion and voids due to poor grouting, one has major corrosion related to construction issues (but appears to have good grout), and one showed no tendon corrosion or grouting problems during the invasive spot checks. Results include recommendations specific to the bridges that were investigated as well as for a general inspection plan for post-tensioned bridges in Minnesota. A concise guide for bridge inspection staff is provided that is specific to post-tensioned bridges.

Project details: